1.0 GENERAL INFORMATION
Thank you for purchasing the Setra Remote Monitoring Display (SRMD). The
SRMD is a digital panel meter with a bright 1” LED display for visibility at a
distance.
Before installing, please check the box and ensure the following items are
included:
1. Mounting Plate (with single or dual display in color(s) ordered:
green, red, or blue)
2. Faceplate Bezel (White or Metallic Finish, as ordered)
3. Engineering units label set
Note: If a dual display is ordered with a SRH temperature or humidity sensor and a color specied to match
each (or your own sensors), wire the correct sensor to the correct display.
The SRMD can be powered by 24 VAC/DC and can accept 0 to 5 or 0 to 10
VDC transducer signals from remote sensors. These field sensors can be tem-
perature, humidity, CO2, etc.
Fig. 1.
Model SRMD
Setra Remote Monitoring Display
Mounting Plate
Grommets for
Faceplate/Bezel
Faceplate/Bezel Engineering Unit Labels
Vue de la page 0
1 2 3 4 5 6 7 8

Résumé du contenu

Page 1 - Model SRMD

1.0 GENERAL INFORMATIONThank you for purchasing the Setra Remote Monitoring Display (SRMD). The SRMD is a digital panel meter with a bright 1” LED dis

Page 2 - 2.1 Rough-In (see Fig 2.)

2.0 INSTALLATION2.1 Rough-In (see Fig 2.)Install the SRMD in a 4 11/16” square electrical box. Run the power and signal wiring into the box. Two wires

Page 3 - Input Wiring

3.0 WIRING TO THE DISPLAYSShown in Fig. 3 is a wiring diagram and picture of the back of the mounting plate. Note that each display has a terminal str

Page 4 - 4.0 CALIBRATION

4.0 CALIBRATIONPower the display(s). If you have the Setra humidity and temperature sen-sor, then the displays are already calibrated and ready to use

Page 5 - 4.3 Adjust Display Brightness

4.2 Zero and Span CalibrationSet the Voltage Source to 0 VDC and Connect the Voltage Source to the +S and COM terminals on the display.Check the field

Page 6 - 5.0 INSTALL MOUNTING PLATE

5.0 INSTALL MOUNTING PLATEAfter adjusting and verifying the depth of the electrical box relative to the finish wall (see, Fig. 2), install the mounting

Page 7 - 6.0 INSTALL FACEPLATE

6.0 INSTALL FACEPLATEThere are 4 pins on the back of the faceplate. Align the pins with the rubber grommets in the mounting plate. Slowly and evenly p

Page 8

7.0 RETURNING PRODUCTS FOR REPAIRWhen returning a product to Setra Systems, the material should be carefully packaged and shipped prepaid to:Setra Sys

Commentaires sur ces manuels

Pas de commentaire